  "document": {
    "acknowledgments": [
      {
        "organization": "CERT@VDE",
        "summary": "coordination",
        "urls": [
          "https://certvde.com"
        ]
      },
      {
        "organization": "Aimon Dawson",
        "summary": "reporting"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE",
        "url": "https://www.first.org/tlp/"
      }
    },
    "lang": "en-GB",
    "notes": [
      {
        "category": "summary",
        "text": "An unauthenticated remote attacker could reset the administrator's password with information from the default, self-signed certificate.",
        "title": "Summary"
      },
      {
        "category": "description",
        "text": "An unathenticated attacker can remotely reset the administrator password.",
        "title": "Impact"
      },
      {
        "category": "description",
        "text": "The certificate is renewed by adjusting the hostname to an own customer-specific, so it does not contain the serial number.",
        "title": "Mitigation"
      },
      {
        "category": "description",
        "text": "The password-reset mechanism will be updated in a future version.\nWhen using automation components, make sure that no unauthorized access can take place. In addition, measures should be taken to ensure that the components do not have direct access to Internet resources and that they cannot be accessed from insecure networks. Use available security measures such as authentication and authorization groups.",
        "title": "Remediation"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "psirt@ifm.com",
      "name": "ifm electronic GmbH",
      "namespace": "https://www.ifm.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "VDE-2022-050: IFM: weak password recovery vulnerability in moneo appliance - HTML",
        "url": "https://certvde.com/en/advisories/VDE-2022-050/"
      },
      {
        "category": "self",
        "summary": "VDE-2022-050: IFM: weak password recovery vulnerability in moneo appliance - CSAF",
        "url": "https://ifm.csaf-tp.certvde.com/.well-known/csaf/white/2022/vde-2022-050.json"
      },
      {
        "category": "external",
        "summary": "Vendor PSIRT",
        "url": "https://www.ifm.com"
      },
      {
        "category": "external",
        "summary": "CERT@VDE Security Advisories for ifm electronic GmbH",
        "url": "https://certvde.com/en/advisories/vendor/ifm/"
      }
    ],
    "title": "IFM: weak password recovery vulnerability in moneo appliance",
    "tracking": {
      "aliases": [
        "VDE-2022-050"
      ],
      "current_release_date": "2026-01-06T11:00:00.000Z",
      "generator": {
        "date": "2026-01-30T08:42:49.132Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.5.42"
        }
      },
      "id": "VDE-2022-050",
      "initial_release_date": "2022-12-12T11:00:00.000Z",
      "revision_history": [
        {
          "date": "2022-12-12T11:00:00.000Z",
          "number": "1.0.0",
          "summary": "Initial revision."
        },
        {
          "date": "2026-01-06T11:00:00.000Z",
          "number": "2.0.0",
          "summary": "fixed version range, added Hardware with relationship, changed vulnerability title to CVE description"
        }
      ],
      "status": "final",
      "version": "2.0.0"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "vers:semver/<=1.9.3",
                    "product": {
                      "name": "moneo appliance <=1.9.3",
                      "product_id": "CSAFPID-51001"
                    }
                  }
                ],
                "category": "product_name",
                "name": "moneo appliance"
              }
            ],
            "category": "product_family",
            "name": "Software"
          },
          {
            "branches": [
              {
                "category": "product_name",
                "name": "QHA210",
                "product": {
                  "name": "QHA210",
                  "product_id": "CSAFPID-11001",
                  "product_identification_helper": {
                    "cpe": "cpe:2.3:h:ifm_electronic:qha210:*:*:*:*:*:*:*:*",
                    "model_numbers": [
                      "QHA210"
                    ]
                  }
                }
              }
            ],
            "category": "product_family",
            "name": "Hardware"
          }
        ],
        "category": "vendor",
        "name": "IFM"
      }
    ],
    "relationships": [
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "moneo appliance <=1.9.3 installed on QHA210",
          "product_id": "CSAFPID-31001"
        },
        "product_reference": "CSAFPID-51001",
        "relates_to_product_reference": "CSAFPID-11001"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-3485",
      "cwe": {
        "id": "CWE-640",
        "name": "Weak Password Recovery Mechanism for Forgotten Password"
      },
      "notes": [
        {
          "category": "description",
          "text": "In IFM Moneo Appliance with version up to 1.9.3 an unauthenticated remote attacker can reset the administrator password by only supplying the serial number and thus gain full control of the device.\n",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-31001",
          "CSAFPID-51001"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "The certificate is renewed by adjusting the hostname to an own customer-specific, so it does not contain the serial number.",
          "product_ids": [
            "CSAFPID-51001",
            "CSAFPID-31001"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "The password-reset mechanism will be updated in a future version.\nWhen using automation components, make sure that no unauthorized access can take place. In addition, measures should be taken to ensure that the components do not have direct access to Internet resources and that they cannot be accessed from insecure networks. Use available security measures such as authentication and authorization groups.",
          "product_ids": [
            "CSAFPID-51001",
            "CSAFPID-31001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "environmentalScore": 9.8,
            "environmentalSeverity": "CRITICAL",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "temporalScore": 9.8,
            "temporalSeverity": "CRITICAL",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-31001",
            "CSAFPID-51001"
          ]
        }
      ],
      "title": "CVE-2022-3485"
    }
  ]
}